      1. +86 532 8281 2277
        Current: Products> Medical Equipments > >Portable Patient Monitor
        Portable Patient Monitor
        Quick Details
        • Type:
        • First-Aid Devices
        • Brand Name:
        • Hiprove
        • Model Number:
        • HPL-9000
        • Place of Origin:
        • Shandong, China (Mainland)
        • Product name:
        • Medical Portable ICU Patient Monitor with good price ISO CE approved
        • Certificate:
        • CE ISO
        • Warranty:
        • 1 year
        • Size:
        • 12.1"
        • Display:
        • Multi channel display
        •  
        Packaging & Delivery
        • Packaging Details:
        • 422637cm, 1 set/carton
        • Delivery Time:
        • Shipped in 30 days after payment
        Product Description

         

        Medical Portable ICU Patient Monitor with good price

         

        Features:

        12.1" color TFT LCD screen, resolution: 800*600
        5 kinds of interfaces: Standard/Big font/6-lead ECG/Trend gragh/OxyCRG
        Maximum 8-channel waveforms display, the waveform color can be defined by user (7 colors)
        96-hour storage and review of trend graphic gram and table, 400 groups NIBP data, 1800 alarm events
        ST and arrhythmia analysis, pacemaker analysis, drug dose calculation
        Anti-defibrillation design
        NIBP over pressure protection
        Plug-in rechargeable battery, AC/DC available
        Support wire or wireless network

        Standard: 3/5-Lead ECG, RESP, SpO2, NIBP, PR, TEMP

        Options: Nellcor SpO2, Mainstream/Sidestream EtCO2, 1/2 channel IBP, Touch screen,

        Thermal Recorder, Wall mount, Trolley

         

        Technical Specifications:

        ECG
        Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
        Lead selection: I, II, III, avR, avL, avF, V
        Wavef orm: 2 ch
        Lead mode: 3 Leads ( R, L, F or RA, LA, LL)
        Lead selection: I, II, III,
        Wave form: 1 ch
        Gain: 2.5mm/mV, 5.0mm/mV,
        10mm/mV,20mm/mV, auto
        HR and Alarm Range: Adult 15 ~ 300 bpm
        Neo/Ped 15 ~ 350 bpm

        Accuracy: ±1% or±1bpm, which is greater
        Resolution: 1 bpm
        Sensitivity: > 200 (uVp-p)
        Differential Input Impedance: > 5 MΩ

        CMRR : Monitor > 105 dB
        Operation > 105 dB
        Diagnosis > 85 dB
        Electrode offset potential: ±300mV
        Leakage Current: < 10 uA
        ECG Signal Range: ±8 m V ( Vp-p )
        Bandwidth:
        Surgery: 1 ~ 20 Hz
        Monitor: 0.5 ~ 40 Hz
        Diagnostic: 0.05 ~ 130 Hz
        Calibration Signal: 1 (mVp-p), Accuracy:5%
        ST Segment Monitoring Range
        Measure and Alarm -2.0 ~ +2.0 mV
        ARR Detecting:
        Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY,
        TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS, PNP,
        PNC,Alarm Available,Review Available


        RESP

        Method : Impedance between R-F(RA-LL)
        Differential Input Impedance: > 2.5 MΩ
        Measuring Impedance Range: 0.3~3 Ω
        Base line Impedance Range: 200~4 KΩ
        Bandwidth: 0.1~2.5Hz
        Resp. Rate:
        Measuring and Alarm Range
        Adult 0 ~ 120 Brpm
        Neo/Ped 0 ~ 150 Brpm
        Resolution 1 Brpm
        Accuracy ±2 Brpm
        Apnea Alarm: 10 ~ 40 S

         

        NIBP

        Method: Oscillometric
        Mode: Manual, Auto, STAT
        Measuring Interval in AUTO Mode :
        1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
        Measuring Period in STAT Mode: 5 Min
        Pulse Rate Range : 40 ~ 240 bpm
        Alarm Type : SYS, DIA, MEAN
        Measuring and alarm range:
        Adult Mode
        SYS: 40 ~ 270 mmHg
        DIA: 10 ~ 215 mmHg
        MEAN: 20 ~ 235 mmHg
        Pediatric Mode
        SYS: 40 ~ 200 mmHg
        DIA: 10 ~ 150 mmHg
        MEAN: 20 ~ 165 mmHg
        Neonatal Mode
        SYS: 40 ~ 135 mmHg
        DIA: 10 ~ 100 mmHg
        MEAN: 20 ~ 110 mmHg
        Resolution: 1mmHg
        Accuracy: Maximum Mean error ±5mmHg
        Maximum Standard deviation ±8mmHg
        Overpressure Protection
        Adult Mode: 297±3 mmHg
        Pediatric Mode: 240±3 mmHg
        Neonatal Mode: 147±3 mmHg
         

        SpO2
        Measuring Range: 0 ~ 100 %
        Alarm Range: 0 ~ 100 %
        Resolution: 1 %
        Accuracy: 70% ~ 100% 2 %
        0% ~ 69%
        Actualization intervalabout: 1 Sec.
        Alarm Delay: 10 Sec.
        Pulse Rate:
        Measuring and Alarm Range 20~300 bpm
        Resolution: 1bpm
        Accuracy: ±3bpm
         

        TEMP
        Channel: 2
        Measuring and Alarm Range : 0 ~ 50 ℃
        Resolution: 0.1 ℃
        Accuracy : ±0.2 ℃
        Actualization intervalabout: 1 Sec.
        Average Time Constant: < 10 Sec.


        IBP

        Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
        Measuring and alarm range:
        ART 0 ~ 300 mmHg
        PA -6 ~ 120 mmHg
        CVP/RAP/LAP/ICP-10 ~ 40 mmHg
        P1 / P2-10 ~ 300 mmHg
        Press Sensor:
        Sensitivity: 5 uV/V/mmHg
        Impedance: 300-3000Ω
        Resolution: 1 mmHg
        Accuracy: ±2% or 1mmHg which is greater
        Actualization interval : about 1 secretar
         

        Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
        Optional: Nellcor SpO2, EtCO2, IBP,TEMP-2, Thermal Recorder,Wall Mount,Trolly,Central station

         

         